Timeouts in TiDB
This document describes various timeouts in TiDB to help you troubleshoot errors.
GC timeout
TiDB's transaction implementation uses the MVCC (Multiple Version Concurrency Control) mechanism. When the newly written data overwrites the old data, the old data will not be replaced, but kept together with the newly written data. The versions are distinguished by the timestamp. TiDB uses the mechanism of periodic Garbage Collection (GC) to clean up the old data that is no longer needed.
For TiDB versions earlier than v4.0:
By default, each MVCC version (consistency snapshots) is kept for 10 minutes. Transactions that take longer than 10 minutes to read will receive an error
GC life time is shorter than transaction duration
.For TiDB v4.0 and later versions:
For running transactions that do not exceed a duration of 24 hours, garbage collection (GC) are blocked during the transaction execution. The error
GC life time is shorter than transaction duration
does not occur.
If you need longer read time temporarily in some cases, you can increase the retention time of MVCC versions:
- For TiDB versions earlier than v5.0: adjust
tikv_gc_life_time
in themysql.tidb
table in TiDB. - For TiDB v5.0 and later versions: adjust the system variable
tidb_gc_life_time
.
Note that the system variable configuration takes effect globally and immediately. Increasing its value will increase the life time of all existing snapshots, and decreasing it will immediately shorten the life time of all snapshots. Too many MVCC versions will impact the performance of the TiDB cluster. So you need to change this variable back to the previous setting in time.
For more information about GC, see GC Overview.
Transaction timeout
GC does not affect ongoing transactions. However, there is still an upper limit to the number of pessimistic transactions that can run, with a limit on the transaction timeout and a limit on the memory used by the transaction. You can modify the transaction timeout by max-txn-ttl
under the [performance]
category of the TiDB profile, 60
minutes by default.
SQL statements such as INSERT INTO t10 SELECT * FROM t1
are not affected by GC, but will be rolled back due to timeout after exceeding max-txn-ttl
.
SQL execution timeout
TiDB also provides a system variable (max_execution_time
, 0
by default, indicating no limit) to limit the execution time of a single SQL statement. Currently, the system variable only takes effect for read-only SQL statements. The unit of max_execution_time
is ms
, but the actual precision is at the 100ms
level instead of the millisecond level.
JDBC query timeout
MySQL JDBC's query timeout setting for setQueryTimeout()
does NOT work for TiDB, because the client sends a KILL
command to the database when it detects the timeout. However, the tidb-server is load balanced, and it will not execute this KILL
command to avoid termination of the connection on a wrong tidb-server. You need to use MAX_EXECUTION_TIME
to check the query timeout effect.
TiDB provides the following MySQL-compatible timeout control parameters.
- wait_timeout, controls the non-interactive idle timeout for the connection to Java applications. Since TiDB v5.4, the default value of
wait_timeout
is28800
seconds, which is 8 hours. For TiDB versions earlier than v5.4, the default value is0
, which means the timeout is unlimited. - interactive_timeout, controls the interactive idle timeout for the connection to Java applications. The value is
8 hours
by default. - max_execution_time, controls the timeout for SQL execution in the connection, only effective for read-only SQL statements. The value is
0
by default, which allows the connection to be infinitely busy, that is, an SQL statement is executed for an infinitely long time.
However, in a real production environment, idle connections and indefinitely executing SQL statements have a negative effect on both the database and the application. You can avoid idle connections and indefinitely executing SQL statements by configuring these two session-level variables in your application's connection string. For example, set the following:
sessionVariables=wait_timeout=3600
(1 hour)sessionVariables=max_execution_time=300000
(5 minutes)